As the leader of drives & controls, V&T Technologies Co., Ltd. are pleased to offer machine automation controllers, servo, AC variable frequency drives as part of our product portfolio.
Item
Model |
3G3JX |
3G3MX2 |
3G3RX |
Appearance |
|
|
|
Power supply and
capacity |
Three-phase 200 V |
0.2
to 7.5 kW |
0.1
to 15 kW |
0.4
to 55 kW |
Single-phase/three-phase 200 V |
0.2 to 2.2 kW |
0.1 to 2.2 kW |
None |
Three-phase 400 V |
0.4 to 7.5 kW |
0.4 to 15 kW |
0.4 to 132 kW |
Control method |
V/f control |
• |
• |
• |
Sensorless vector
control |
|
• |
• |
Vector control
with a PG |
|
|
• |
Input/output |
No. of
multi-function I/O points |
• 5 inputs
• 1 transistor output
• 1 relay output |
• 7 inputs
• 2 transistor outputs
• 1 relay output
|
• 9 inputs (1 RUN (FWD)
input + 8 multi-function inputs)
• 5 transistor outputs
• 1 relay output |
Analog I/O |
• 1 input (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V) |
• 2 inputs
(0 to 10 V, 4 to 20 mA) •
1 output
(0 to 10 V) |
• 2 inputs (1) 0 to 10 V, 4 to 20 mA (2) 0 to ±10 V
• 2 outputs (1) 0 to 10 V (2) 4 to 20 mA
• 1 PWM voltage output |
Safety
|
Dual STO output |
|
• |
|
EDM output |
|
• |
|
Braking |
Braking resistor
connection |
|
• |
• (22 kW max.) |
Regenerative
Braking Unit connection |
• |
• |
• |
Regenerative
Braking Unit + braking resistor connection |
• |
• |
• |
Frequency |
Frequency setting
range |
0.5
to 400 Hz |
0.1 to 400 Hz |
0.1 to 400 Hz |
Frequency output
method |
Line-to-line sine wave PWM |
Installation and
wiring
|
Side-by-side
mounting |
• |
• |
|
Removable terminal
block |
|
|
• |
Power supply and
motor wiring |
Top/bottom
wiring |
Bottom wiring |
Noise
counter-measures |
Radio noise filter |
Standard feature (built-in) |
Optional
(external) |
Standard
feature (built-in) |
I/O noise filter |
Optional
(external) |
EMC filter |
Optional
(external) |
Standard
feature (built-in) |
Operation |
Digital Operator |
Fixed Digital
Operator (with adjustment dial) |
Fixed
Digital Operator
(without adjustment dial) |
Removable
Digital Operator
(without adjustment dial) |
Autotuning |
|
• |
• |
Main functions |
Multistep speed
control |
16 steps +
jog |
Carrier frequency
setting |
2 to 12 kHz
(default setting: 3 kHz) |
2 to 15 kHz
(default setting: 10 kHz) |
2 to 15 kHz
(default setting: 5 kHz) |
Torque assist
function |
Manual + auto
torque assist |
Auto
(simple)/manual torque assist |
Auto/manual
torque assist |
PID function |
• |
• |
• |
Absolute value
positioning |
|
• |
• |
Emergency shutoff |
• |
• |
• |
0-Hz domain
sensorless vector control |
|
|
• |
Tripless function |
• |
• |
• |
Momentary power
interruption restart |
• |
• |
• |
Automatic energy
saving |
• |
|
• |
Communications |
MODBUS-RTU |
• |
• |
• |
RoHS |
• |
• |
• |
Safety standards |
CE |
• |
• |
• |
UL/cUL |
• |
• |
• |
PLd |
|
•
(ISO 13849-1: 2006) |
|