E5-P PID feedback closed loop control VFD for variable torque, light duty
V&T EcoDriveCN® E5-P AC variable speed drive (VSD) for variable torque, light duty
Technical Specifications of E5-P PID closed loop control AC drives (variable speed drives, VSD, VFD)
User manual of E5-P vector control and built-in PID controller AC variable frequency drive.
With complete applications for water supply, with high efficiency, stable pressure, reliable, simple operation, easy installation, small footprint, low noise, no pollution, low investment, effective advantages.
Rich function of
built-in PID controller for feedback closed loop control.
Parameters copy function.
failure rate: < 0.15%, just the same as other world-class traditional brands, such as
Siemens, ABB, Emerson, Schneider, Allen Bradley, Lenze, Yaskawa, Mitsubishi, Omron
authorized CE, issued by
ECMG
long warranty period: 18 months, favorable to clients
delivery lead time: 1-3 days
supply to
REGAL, Ingersoll Rand, Tata group, Foxconn, Tata group...
Power(KW) |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
Motor Power(KW) |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
Output |
Voltage(V) |
3 phase 0V to rated input voltage |
Rate current(A) |
3.3 |
5.0 |
7.5 |
11 |
17 |
22 |
30 |
38 |
45 |
57 |
75 |
91 |
112 |
142 |
176 |
Overload
capability |
120% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input |
Rated
voltage/frequency |
3 phase 380V/480V; 50Hz/60Hz |
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness <=3%; allowable frequency fluctuation: +-5% |
Rate current(A) |
5.6 |
8.1 |
13.5 |
19.5 |
26 |
39 |
50.3 |
60 |
69.3 |
86 |
104 |
124 |
150 |
190 |
235 |
Braking unit |
Built-in as standard |
External braking unit needed |
Protection class |
IP20 (NEMA 1). IP65 is optional. |
Cooling mode |
Self-cooling |
Forced air cooling |
Power(KW) |
110 |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
560 |
.. |
Motor Power(KW) |
110 |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
560 |
|
Output |
Voltage(V) |
3 phase 0V to rated input voltage |
Rate current(A) |
210 |
253 |
304 |
350 |
380 |
426 |
470 |
520 |
600 |
650 |
690 |
775 |
860 |
950 |
|
Overload capability |
120% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input |
Rated voltage/frequency |
3 phase 380V/480V; 50Hz/60Hz |
Allowable voltage range |
323V ~ 528V; Voltage unbalancedness <=3%; allowable frequency fluctuation: +-5% |
Rate current(A) |
196* |
232* |
282* |
326* |
352* |
385* |
437* |
491* |
580* |
624* |
670 |
755* |
840* |
920* |
|
Braking unit |
External braking unit needed |
Protection class |
IP20 (NEMA 1). IP65 is optional. |
Cooling mode |
Forced air cooling |
Remark: For E5-P-4T110 and larger power frequency inverter, external DC reactor is configured.