V&T EcoDriveCN® drives V&T inverters
explosion proof VFD,HazLoc softstarter, motor soft starter, vector control variable speed drive (VSD, variable frequency drive, AC drive, inverter), reactor, sine wave filters, power electronics: quality as ABB, Siemens.

AC spindle servo drive

AC spindle servo drive

V&T EcoDriveCN® C spindle servodrive for CNC, machine tools



description      technical


  technical specification technical specification
output Max output voltage (V) 3 phase 380V/400V/415V/440V equivalent input voltage
Max output rotation (A) 18000 rpm
input rated voltage/frequency 3 phase 380V/400V/415V/440V,  50Hz ~ 60Hz ±5%
Allowable voltage fluctuation +10%, -15%
control characteristic control mode Sine wave PWM control, full closed loop vector control
speed adjustment range 1:5000
speed control precision ± 0.0.15%
position control precision ±1 Pulse
frequency setting resolution digital: 0.01Hz; analog: bipolar. Max output frequency/2048 remark: high precision (bipolar, max output frequency/16384) analog input is optional
acceleration 0.05~1000Hz/s
brake mode dynamicbraking; built-in brake unit
input/output interface digital input 7 channel opto isolated inputs; input method: PNP or NPN
digital output

2 channel opto isolated output; 24V 10mA
analog input 3 channel: -10V ~ 10V
analog output 3 channel
relay output 1 channel: a set of normally open / normally closed contact: AC250V/DC30V, 1A
failure output relay 1 channel: a set of normally open / normally closed contact: AC250V/DC30V, 1A
encoder input interface 1: max accepted frequency 300k Hz; line drive; RS422 standard
pulse input interface 1: direction pulse or orthogonal pulse
encoder output interface 1: max accepted frequency 300k Hz; line drive; RS422 standard
bus interface RS232, CAN, ethernet
spindle function speed control range: 0~18000rpm; direction: foward/reverse; speed indicator: analog, pulse frequency, bus
stop positioning precision: ±1 Pulse; position adjustment: user parameter setting
rigid tapping work normally with many systems, tapping error: 2%
other functions C-axis control, thread cutting, electronic gear, reaming, swing control
motor overload alarm output if overload alarm value is more than the specified time; by parameter setting
abnormal output of short circuit to earth alarm output, when output is short circuit to earth
abnomal output of lacking phase alarm output when output losing phase
applied environment applied place No dust, no corrosive gas, no flammable gas
temperature -10ºC ~ 40ºC, degrade during 40ºC ~ 50ºC. Each 1ºC up, decrease 0.15% rated current
humidity 5 ~ 95%, no condensing
vibration vibration frequency <= 20Hz: 9.8m/s2; 20Hz <= vibration frequency <= 50Hz: 2m/s2
FaceBook  twitter  LinkedIn  Photo Gallery  |CE certificate  |superb components
© 2016 V&T All rights reserved.
ECMG, NVLAP, CE

Our Expertise Is Your Guarantee!

Leading manufacturer and supplier industrial automation, motor control, motion control and energy efficiency.