technical specification
|
output
|
Max output voltage (V)
|
3 phase 380V/400V/415V/440V equivalent input voltage
|
Max output rotation (A)
|
18000 rpm
|
input
|
rated voltage/frequency
|
3 phase 380V/400V/415V/440V, 50Hz ~ 60Hz ±5%
|
Allowable voltage fluctuation
|
+10%, -15%
|
control characteristic
|
control mode
|
Sine wave PWM control, full closed loop vector control
|
speed adjustment range
|
1:5000
|
speed control precision
|
± 0.0.15%
|
position control precision
|
±1 Pulse
|
frequency setting resolution
|
digital: 0.01Hz; analog: bipolar. Max output frequency/2048
remark: high precision (bipolar, max output frequency/16384) analog input is optional
|
acceleration
|
0.05~1000Hz/s
|
brake mode
|
dynamicbraking; built-in brake unit
|
input/output interface
|
digital input
|
7 channel opto isolated inputs; input method: PNP or NPN
|
digital output
|
2 channel opto isolated output; 24V 10mA
|
analog input
|
3 channel: -10V ~ 10V
|
analog output
|
3 channel
|
relay output
|
1 channel: a set of normally open / normally closed contact: AC250V/DC30V, 1A
|
failure output relay
|
1 channel: a set of normally open / normally closed contact: AC250V/DC30V, 1A
|
encoder input interface
|
1: max accepted frequency 300k Hz; line drive; RS422 standard
|
pulse input interface
|
1: direction pulse or orthogonal pulse
|
encoder output interface
|
1: max accepted frequency 300k Hz; line drive; RS422 standard
|
bus interface
|
RS232, CAN, ethernet
|
spindle function
|
speed control
|
range: 0~18000rpm; direction: foward/reverse; speed indicator: analog, pulse frequency, bus
|
stop positioning
|
precision: ±1 Pulse; position adjustment: user parameter setting
|
rigid tapping
|
work normally with many systems, tapping error: 2%
|
other functions
|
C-axis control, thread cutting, electronic gear, reaming, swing control
|
motor overload
|
alarm output if overload alarm value is more than the specified time; by parameter setting
|
abnormal output of short circuit to earth
|
alarm output, when output is short circuit to earth
|
abnomal output of lacking phase
|
alarm output when output losing phase
|
applied environment
|
applied place
|
No dust, no corrosive gas, no flammable gas
|
temperature
|
-10ºC ~ 40ºC, degrade during 40ºC ~ 50ºC. Each 1ºC up, decrease 0.15% rated current
|
humidity
|
5 ~ 95%, no condensing
|
vibration
|
vibration frequency <= 20Hz: 9.8m/s2; 20Hz <= vibration frequency <= 50Hz: 2m/s2
|